BS215 100mm2 Aluminum Power Cable Anti Corrosion AAC Conductor

Basic Information
Place of Origin: China
Brand Name: OEM
Certification: ISO 9001:2015, ISO 14001:2005, CE;
Minimum Order Quantity: Negotiable
Price: Negotiation
Packaging Details: Standard export package
Delivery Time: 15-20 working days or Negotiation
Payment Terms: T/T, L/C, D/P, West Union, Paypal, Secure Payments
Material: Hard Drawn Aluminum Wire Out Sheath Color: None
Core: Normal OR CUSTOMIZED Cable Drum Length: Wooden
Characted: Bare Conductor Nominal Area: 16-1000sqmm
Jacket: None Application: Overhead Line
High Light:

100mm2 Aluminum Power Cable

,

BS215 Aluminum Power Cable

,

100mm2 3 phase aluminum cable

BS215 All Aluminium Conductor 100mm2 AAC

 

APPLICATION

Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution.

AAC conductors is used mainly in urban areas where the spacing is short and the supports are closer together.

The advantage of AAC conductors is that they have a high degree of corrosion resistance;for this reason they are used extensively in coastal areas.

 

STANDARD

ASTMB231
BS215 Part1
DIN48201
IEC61089

 

All Aluminum Conductor CONSTRUCTION PARAMETERS

ASTm B 231/B 231m

Code Nominal Area Stranding Overall
Diameter
Weight Rated
Strength
Electrical
Resistance
Current
Rating*
AWG&MCM mm² No.x mm mm Kg/Km KN Ω/Km A
Peachbell 6 13.3 7/1.56 4.68 36.6 2.53 2.1477 75
Rose 4 21.1 7/1.96 5.88 58.2 3.91 1.3606 99
Iris 2 33.6 7/2.47 7.41 92.6 5.99 0.8567 132
Pansy 1 42.4 7/2.78 8.34 116.6 7.3 0.6763 153
Poppy 1/0.0 53.5 7/3.12 9.36 147.2 8.84 0.5369 176
Aster 2/0.0 67.4 7/3.50 10.5 185.7 11.1 0.4267 203
Phlox 3/0.0 85 7/3.93 11.79 233.9 13.5 0.3384 234
Oxlip 4/0.0 107.2 7/4.42 13.26 295.2 17 0.2675 270
Valerian 250 126.7 19/2.91 14.55 348.6 20.7 0.2274 299
Tulip 336.4 170.5 19/3.38 16.9 469.5 27.3 0.1686 359
Orchid 636 322.3 37/3.33 23.31 886.9 50.4 0.0892 530
Magnolia 954 483.4 37/4.08 28.56 1331 72.6 0.0594 676

 

IEC 61089

Code Nominal Area Stranding Overall
Diameter
Weight Rated
Strength
Electrical
Resistance
Current
Rating*
mm² No.x mm mm Kg/Km KN Ω/Km A
10 10 7/1.35 4.05 27.4 1.95 2.8633 62
16 16 7/1.71 5.13 43.8 3.04 1.7896 84
25 25 7/2.13 6.39 68.4 4.5 1.1453 110
40 40 7/2.70 8.1 109.4 6.8 0.7158 147
63 63 7/3.39 10.17 172.3 10.39 0.4545 195
100 100 19/2.59 12.95 274.8 17 0.2877 259
125 125 19/2.89 14.45 343.6 21.25 0.2302 297
160 160 19/3.27 16.35 439.8 26.4 0.1798 345
200 200 19/3.66 18.3 549.7 32 0.1439 396
250 250 19/4.09 20.45 687.1 40 0.1151 454
315 315 37/3.29 23.03 867.9 51.97 0.0916 522
630 630 61/3.63 32.67 1738.3 100.8 0.0458 789

aaac conductor model and sizes

     

 

 

 Why you choose us?

Contact Details