Place of Origin:
China
Brand Name:
OEM
Certification:
ISO 9001:2015, ISO 14001:2005, CE;
BS215 All Aluminium Conductor 100mm2 AAC
Applications
Stranded 1350 aluminum conductors shown in this section of data are classified as follows:
Class AA For bare conductors usually used in overhead lines.
Class A For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required.
Compact strand conductor for use in bare overhead applications or for use with weather-resistant coverings or insulations is also available.
Classes refer to stranding and are an indication of relative conductor flexibility, AA being the least flexible, C the most flexible.
Construction
Aluminum alloy 1350-H19 wires, concentrically stranded. 
STANDARD
ASTMB231,BS215 Part1,DIN48201,IEC61089
All Aluminum Conductor CONSTRUCTION PARAMETERS
ASTm B 231/B 231m
| Code | Nominal Area | Stranding | Overall Diameter  | 
			Weight | Rated Strength  | 
			Electrical Resistance  | 
			Current Rating*  | 
		|
| AWG&MCM | mm² | No.x mm | mm | Kg/Km | KN | Ω/Km | A | |
| Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.53 | 2.1477 | 75 | 
| Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.91 | 1.3606 | 99 | 
| Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 5.99 | 0.8567 | 132 | 
| Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 | 153 | 
| Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.84 | 0.5369 | 176 | 
| Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 | 203 | 
| Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 | 234 | 
| Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 | 270 | 
| Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 | 299 | 
| Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 | 359 | 
| Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 | 530 | 
| Magnolia | 954 | 483.4 | 37/4.08 | 28.56 | 1331 | 72.6 | 0.0594 | 676 | 
IEC 61089
| 
			 Specification No. 
  | 
			
			 Nominal cross section mm² 
  | 
			
			 No.of single wire 
  | 
			
			 Diameter mm  | 
			
			 Unit length weight kg/km 
  | 
			
			 Rating tension resistance kN 
  | 
			
			 DC resistance 20℃ Ω/km 
  | 
		|
| Single wire | Stranded wire | ||||||
| 
			 10 16 25 40 63  | 
			
			 10 16 25 40 63  | 
			7 | 
			 1.35 1.71 2.13 2.7 3.39  | 
			
			 4.05 5.12 6.40 8.09 10.2  | 
			
			 27.4 43.8 68.4 109.4 172.3  | 
			
			 1.95 3.04 4.50 6.80 10.39  | 
			
			 2.8633 1.7896 1.1453 0.7158 0.4545  | 
		
| 
			 100 125 160 200 250  | 
			
			 100 125 160 200 250  | 
			
			 19 
  | 
			
			 2.59 2.89 3.27 3.66 4.09  | 
			
			 12.9 14.5 16.4 18.3 20.5  | 
			
			 274.8 343.6 439.8 549.7 687.1  | 
			
			 17.00 21.25 26.40 32.00 40.00  | 
			
			 0.2877 0.2302 0.1798 0.1439 0.1151  | 
		
| 
			 315 400 450 500 560  | 
			
			 315 400 450 500 560  | 
			37 | 
			 3.29 3.71 3.94 4.15 4.39  | 
			
			 23.0 26.0 27.5 29.0 30.7  | 
			
			 867.9 1102.0 1239.8 1377.6 1542.9  | 
			
			 51.97 64.00 72.00 80.00 89.60  | 
			
			 1.0916 0.0721 0.0641 0.0577 0.0515  | 
		
| 
			 630 710 800 900 1000  | 
			
			 630 710 800 900 1000  | 
			61 | 
			 3.63 3.85 4.09 4.33 4.57  | 
			
			 32.6 34.6 36.8 39.0 41.1  | 
			
			 1738.3 1959.1 2207.4 2483.3 2759.2  | 
			
			 100.80 113.60 128.00 144.00 160.00  | 
			
			 0.0458 0.0407 0.0361 0.0321 0.0289  | 
		
| 
			 1120 1250 1400 1500  | 
			
			 1120 1250 1400 1500  | 
			91 | 
			 3.96 4.18 4.43 4.58  | 
			
			 43.5 46.0 48.7 50.4  | 
			
			 3093.5 3452.6 3866.9 4143.1  | 
			
			 179.2 200.00 224.00 240.00  | 
			
			 0.0258 0.0231 0.0207 0.0193  | 
		
Why you choose us?
Send your inquiry directly to us